WISERISE Water Mist Fire Protection

Fixed Water Mist Fire Extinguishing Systems · Engine-Room Local Application · Full-Ship Passenger Solutions

Water Mist Fire Extinguishing Systems (High / Low-Pressure)

WISERISE specializes in engine-room local water mist and full-ship passenger water mist solutions. We also undertake retrofit projects—ensuring compatibility with existing systems and optimizing flow and piping networks. Critical spares are stocked in Shanghai and Singapore for rapid AOG support and class-compliant repairs.

In-Stock Spares (SHA / SIN) Pumps, nozzles, valves, filters, sections & fittings—ready for immediate dispatch.
Retrofit & Expansion New/legacy compatibility, flow re-balancing, network optimization, minimal downtime.
Class-Ready Documentation Submittals, calculations, drawings, and commissioning records ready for class review.

Water Mist Applications

Engine-room local protection, full-ship passenger coverage, retrofits, and life-extension adaptations.

💧
Engine-Room Local
Pump rooms, purifier rooms, main engine surroundings—rapid oil-fire knockdown and radiant heat reduction.
🛳️
Passenger Ship Full Coverage
Cabins, public areas, corridors, technical spaces—fine mist for visibility control and re-ignition suppression.
🧰
Retrofit & Expansion
Pump upgrades, nozzle replacement, piping verification, valve renewals, and control panel integration.
⚙️
High / Low-Pressure
Multi-brand compatibility; spray density per heat release rate and accessibility.
🧪
Design & Verification
Hydraulic calculations, nozzle layouts, coverage overlap, smoke/thermal flow checks.
🔄
Compatibility & Life Extension
Obsolete part replacement and integration with detection, ventilation and shutdown systems.

Water Mist Project Delivery Flow

From technical enquiry to lifecycle service—reliable and class-approved water mist protection.

01
Requirement Capture
Protected spaces, class/flag, scope (local/full-ship), constraints.
02
Survey & Hydraulic Data
Pump capacity, nozzle positioning, pipe routing feasibility.
03
Engineering & Class Submittal
Hydraulic calcs, spray density, overlap maps, GA & manuals for ABS/DNV/LR/CCS.
04
Procurement & Fabrication
OEM pumps, filters, nozzles, valves, panels; FAT as required.
05
Installation & Commissioning
Flushing/pressure tests, nozzle flow, cause–effect and interlock tests.
06
Handover & Lifecycle Support
Dossiers, crew training, spares, periodic inspection/maintenance.

Compliance & Classification

Design & documentation comply with international standards, flag & port state requirements; aligned with class approvals and onboard inspections.

📄
Engine/Pump Room Water Mist Guidelines
📄
Passenger/Public Area Fine Mist Standards
📄
Flag & Port State Requirements
📄
ABS • LR • DNV • CCS • BV
📄
Test Records & Reporting Packages
📄
Maintenance / Drill / Training Materials

Inventory Snapshot

Critical spare parts in Shanghai & Singapore, supporting newbuilds and operating-vessel retrofits.

🧩
Nozzles & Filters
Critical models ready; 24–72h dispatch to East/South China ports.
🧰
Valves & Actuators
Key valves/execution units for fast restoration.
🚿
HP Pumps & Stabilizers
For urgent upgrades or replacements.
🧵
Hoses & Fittings
Flexible assemblies & joints for compliance repairs.
🧠
Control Boards & Panels
Release/interface modules for class-ready repairs.
🧪
Test Tools & Consumables
N₂ blow-through kits, gauges & service consumables.
🧩
Nozzles & Filters
Passenger & offshore models; 24–72h dispatch across SE Asia.
🧰
Valves & Actuators
Conversions and quick port-call support.
🚿
HP Pumps & Stabilizers
Ready-to-install Skids for yard projects.
🧵
Hoses & Fittings
Assemblies & fittings for urgent replacement.
🧠
Control Boards & Panels
Release/interface panels for smooth commissioning.
🧪
Test Tools & Consumables
Tools and gauges supporting regional service teams.

Customer Guidance & Applications

What we need to quote, how to start, and where high/low-pressure water mist applies.

📝 Information Required for Quotation
  • Vessel name/type & IMO number; protected spaces & volumes
  • Class & flag requirements; newbuild / retrofit / add-on scope
  • Preferred delivery time & port; special interlocks/integration

With these, our Shanghai & Singapore teams deliver a class-compliant proposal fast.

⚙️ High-Pressure vs. Low-Pressure
  • High-Pressure: Engine & pump rooms, turbines, machinery spaces—fast atomization & cooling.
  • Low-Pressure: Passenger cabins, public areas, corridors, technical spaces—visibility & re-ignition control.
  • Both integrate with detection, ventilation shutdown & emergency interlocks.

Selection depends on heat release rate, coverage density, and accessibility.

WISERISE Marine Fire & Safety Systems

Singapore brand for marine fire protection systems and safety technologies.

Systems

  • CO₂ Fire Extinguishing
  • Dry Chemical Powder
  • Water Mist
  • Inert Gas (IG)
  • Foam Firefighting
  • Oxygen–Acetylene (AC–OX)
  • Medical Oxygen
  • Breathing Gas Supply (BGS)
  • Fire Detection & Alarm

Sectors

  • Engine Room & Machinery
  • Main Deck & Cargo
  • Galley & Ducts
  • Helideck
  • Special Compartments
  • H₂S Work Environments

Contact

WISERISE MARINE PTE LTD
Add: 1 SCOTTS ROAD, #24-10 SHAW CENTRE, SINGAPORE 228208
MOB: +65 8833 6706
WeChat/WhatsApp/Line: +65 8866 9059

Shanghai WISERISE Ship Management Co., Ltd
Add: Building 5, No.39 Luda Road, Pudong New District, Shanghai, China 201322
Tel: +86 021 5815 2905

© 2025 WISERISE Marine Fire & Safety Systems. All rights reserved. Privacy Policy