🌍Singapore • Global Projects

MARINE FIRE & SAFETY TECHNOLOGY

Integrated Fire Protection for Ships & Offshore Assets

Powered by WISERISE

Request a Proposal
WISERISE Medical Gas for Ships

Medical Oxygen Gas System for Vessels

Class-aligned medical oxygen solutions for ship hospitals and treatment rooms—covering cylinder supply, distribution, regulation, safety interlocks, documentation, and lifecycle service.

IMO / MFAG Aligned · Onboard oxygen therapy readiness
Turnkey · Design · Supply · Commissioning · Crew training
Spares in SHA / SIN · Cylinders · Regulators · Flowmeters · Hoses

Applications

Oxygen therapy infrastructure tailored to shipboard healthcare—from routine care to emergency response.

Ship Hospital / Treatment Room
Primary oxygen point(s) with dual-outlet regulators and flowmeters.
Portable Resuscitation Sets
Ready-to-use 2 L/200 bar sets with masks for on-scene response.
Outpatient / Isolation Areas
Additional outlets or portable kits for infectious disease isolation spaces.
Basic Pipeline Runs
Short medical-gas pipework within the hospital zone, with shut-off valves and alarms where required.
Cruise / Offshore Clinics
Expanded outlet counts, manifolded cylinder banks, and monitoring.
Training & Drills
Crew familiarization for equipment checks, changeovers, and oxygen therapy procedures.

Project Delivery Flow

From medical needs assessment to class handover—documentation, commissioning, and training included.

01
Needs & Capacity
Define patient loads, therapy duration, outlet count, minimum oxygen reserve, and portable set needs.
02
Layout & Safety
Hospital layout, cylinder store (ventilation, segregation, signage), regulator/flowmeter specs, hose routing.
03
Engineering & Docs
Manifolds, shut-offs, pressure relief, labeling; test & maintenance plans; medical logs and manuals.
04
Supply & Fabrication
Cylinders, regulators, gauges, flowmeters, outlets, hoses, brackets; QA with certificates.
05
Commissioning
Pressure/leak checks, outlet verification, cleaning (oil/grease-free), oxygen-enrichment risk briefing.
06
Handover & Training
Crew training, drills, maintenance schedule, periodic cylinder test calendar, replenishment plan.

Compliance & Classification

Designs aligned with IMO medical guidance, MFAG/IMGS provisioning, cylinder test intervals and medical gas pipeline best practices.

Medical Oxygen Provisioning
WHO IMGS & MFAG-based onboard oxygen therapy capability.
Minimum Oxygen Reserve
Typical flag guidance: hospital set plus portable set ready for use.
Cylinder Inspection & Testing
Periodic inspection/hydrotest intervals per flag/MGN & cylinder standards.
Storage & Handling
Dedicated ventilated store, segregation, no oil/grease, correct signage/labeling.
Pipeline Practices
Where piped systems are fitted, follow ISO 7396-1 principles (materials, cleanliness, testing).
Class & Records
ABS • LR • DNV • CCS • BV documentation, logs, drills & maintenance records.

Inventory Snapshot — Medical Oxygen

Critical spares staged in Shanghai & Singapore for rapid compliance repairs and replenishment.

Medical O₂ Cylinders
40 L / 200 bar hospital cylinders; 2 L / 200 bar portable sets with brackets and trolleys.
Regulators & Flowmeters
Dual-outlet regulators, pressure gauges, humidifiers, masks and tubing sets.
Manifolds & Hoses
Changeover manifolds, oxygen-clean hoses & quick connectors, shut-off valves.
Outlets & Accessories
Bedhead outlets, check valves, labeling/ID plates, warning signs.
Testing & Service Kits
Leak test gear, cleaning kits (oil-free), flow verification tools.
Logs & Documentation
Medical logs, cylinder test calendar sheets, crew checklists & drill templates.

Customer Guidance & Applications

What we need to quote, how to start with WISERISE, and where medical oxygen is applied onboard.

Information Required for Quotation
  • Vessel type & IMO; hospital layout and intended outlet count
  • Required reserve (therapy duration & patient concurrency)
  • Flag/class requirements & cylinder test regime; preferred ports
  • Storage location & ventilation; signage/labeling expectations
  • Need for pipeline runs, shut-off valves, alarms or monitoring

We deliver class-ready drawings, test plans, logs, and crew training packages.

Typical Shipboard Applications
  • Primary hospital oxygen with dual-outlet regulator and flowmeters
  • One portable resuscitation set ready for immediate deployment
  • Optional short pipeline to bedside outlet(s) with local shut-off
  • Periodic cylinder inspection/hydrotest scheduling and replenishment plan

Safety: Oxygen-enriched atmospheres increase fire risk. Keep oil/grease away, store in ventilated areas, and train crew in handling and changeover.

WISERISE Marine Fire & Safety Systems

Singapore brand for marine fire protection systems and safety technologies.

Systems

  • CO₂ Fire Extinguishing
  • Dry Chemical Powder
  • Water Mist
  • Inert Gas (IG)
  • Foam Firefighting
  • Oxygen–Acetylene (AC–OX)
  • Medical Oxygen
  • Breathing Gas Supply (BGS)
  • Fire Detection & Alarm

Sectors

  • Engine Room & Machinery
  • Main Deck & Cargo
  • Galley & Ducts
  • Helideck
  • Special Compartments
  • H₂S Work Environments

Contact

WISERISE MARINE PTE LTD
Add: 1 SCOTTS ROAD, #24-10 SHAW CENTRE, SINGAPORE 228208
MOB: +65 8833 6706
WeChat/WhatsApp/Line: +65 8866 9059

Shanghai WISERISE Ship Management Co., Ltd
Add: Building 5, No.39 Luda Road, Pudong New District, Shanghai, China 201322
Tel: +86 021 5815 2905

© 2025 WISERISE Marine Fire & Safety Systems. All rights reserved. Privacy Policy