🌍Singapore • Global Projects

MARINE FIRE & SAFETY TECHNOLOGY

Integrated Fire Protection for Ships & Offshore Assets

Powered by WISERISE

Request a Proposal
WISERISE Dry Chemical Powder Systems

Fixed Dry Chemical Powder for LNG-Fuelled Ships

DCP systems provide rapid knockdown for LNG leaks and pool fires at bunkering stations and gas handling areas. We engineer class-approved packages for newbuilds and retrofits, with spares staged in Shanghai & Singapore.

IGF Code Ready · Bunkering station coverage · Manual-safe release
LNG Trend · Essential for gas-fuel bunkering safety
Turnkey · Design · Supply · Commissioning · Lifecycle service

Applications

Targeted, fast-acting suppression for LNG fuel systems and gas-handling interfaces on dual-fuel and gas-fuelled ships.

LNG Bunkering Stations
Fixed DCP coverage for all potential leak points; manual release from a safe location.
Drip Trays & Transfer Manifolds
Rapid knockdown for pool fires during bunkering/transfer operations.
Tank Connection Spaces
Supplementary protection for gas valve units and hazardous zones as required by design.
Vent/Mast & Gas Handling Areas
Local coverage at critical interfaces; coordinated with shutdown and ESD logic.
Retrofit & Conversion
Add DCP to legacy LNG-fuel installations to meet current class interpretations.
Cargo Gas (IGC Scope)
For LNG carriers: on-deck cargo areas protected by fixed DCP per IGC requirements.

Project Delivery Flow

Aligning with IGF/IGC requirements—from bunkering hazard study to commissioning and class handover.

01
Hazard & Scope
Identify bunkering station layout, leak points, drip trays, valve units, hazardous zones.
02
Capacity & Coverage
Define DCP discharge rate and duration; locate nozzles to effectively blanket leak sources.
03
Engineering & Class Submittal
Nozzle maps, piping, actuation & ESD interfaces, manuals; submit to ABS/LR/DNV/CCS/BV.
04
Supply & Fabrication
DCP cylinders, valves, manifolds, hoses, release panels; FAT as required by class.
05
Installation & Commissioning
Functional tests, discharge checks, interlock & shutdown verification at bunkering stations.
06
Handover & Lifecycle
Class dossiers, crew training, maintenance/inspection schedule, refills and periodic tests.

Compliance & Classification

Designed to meet bunkering safety expectations for LNG-fuelled ships and cargo gas rules for LNG carriers.

IGF Code – Gas-fuelled Ships
Bunkering stations require fixed DCP with safe manual release.
IGC Code – Gas Carriers
On-deck cargo areas fitted with fixed DCP systems.
Revised DCP Approval Guidelines
Latest approval guidance for fixed DCP systems on liquefied gas ships.
Class: ABS • LR • DNV • CCS • BV
Submission, FAT/SAT witnessing per class practice.
ESD/Shutdown Integration
Aligned with fuel gas safety functions and hazardous area controls.
Records & Training
Commissioning records, drills, periodic testing & powder quality checks.

Inventory Snapshot — DCP

Critical spares in Shanghai & Singapore for LNG bunkering stations and gas handling areas.

DCP Cylinders & Valves
Approved powder cylinders, discharge valves, pressure gauges, bursting discs; refill & recert support.
Manifolds & Hoses
Main/sectional manifolds, high-flow hoses and fittings for bunkering coverage.
Nozzles & Discharge Devices
Full-bore nozzles and applicators for effective powder dispersion.
Release Panels & Interfaces
Manual-safe release, interlocks to ESD/ventilation; local indicators & alarms.
Detection & Integration Modules
Interface to gas detection, shutdowns, ventilation & fuel isolation.
Test Tools & Consumables
Discharge verification kits, seals, labels and commissioning consumables.

Customer Guidance & Applications

Key information to prepare for quotation and the main use cases where Dry Chemical Powder systems bring the highest value on LNG-fuelled vessels.

Information Required for Quotation
  • Vessel type & IMO number, GA of bunkering station and gas valve units
  • Class and flag requirements; newbuild or retrofit scope
  • Preferred delivery schedule and ports of installation
  • Interfaces: gas detection, ESD/shutdowns, ventilation, alarms and HMI
  • Required discharge performance (rate and duration) and safe release location

We prepare class-ready drawings, manuals, and test records to support approval and onboard inspection.

Recommended Use Cases
  • LNG bunkering stations and drip trays for rapid knockdown of gas leaks and pool fires
  • Transfer manifolds and connection areas with potential leak sources
  • Cargo deck zones on LNG carriers in accordance with IGC Code requirements
  • Integration with water mist or foam systems to create layered fire protection

Note: DCP systems are specialized and require periodic maintenance and powder quality checks. They are not a replacement for total-flooding systems inside machinery spaces.

WISERISE Marine Fire & Safety Systems

Singapore brand for marine fire protection systems and safety technologies.

Systems

  • CO₂ Fire Extinguishing
  • Dry Chemical Powder
  • Water Mist
  • Inert Gas (IG)
  • Foam Firefighting
  • Oxygen–Acetylene (AC–OX)
  • Medical Oxygen
  • Breathing Gas Supply (BGS)
  • Fire Detection & Alarm

Sectors

  • Engine Room & Machinery
  • Main Deck & Cargo
  • Galley & Ducts
  • Helideck
  • Special Compartments
  • H₂S Work Environments

Contact

WISERISE MARINE PTE LTD
Add: 1 SCOTTS ROAD, #24-10 SHAW CENTRE, SINGAPORE 228208
MOB: +65 8833 6706
WeChat/WhatsApp/Line: +65 8866 9059

Shanghai WISERISE Ship Management Co., Ltd
Add: Building 5, No.39 Luda Road, Pudong New District, Shanghai, China 201322
Tel: +86 021 5815 2905

© 2025 WISERISE Marine Fire & Safety Systems. All rights reserved. Privacy Policy